Battery Test System CT3002A/CT3002AU

Battery Test System CT3002A and CT3002AU are the latest models with dual current ranges and highly accurate current/voltage tests.

CT3002AU.jpg
Battery Test System CT3002AU (for current FS 1mA~100mA, 1U, ~11lbs)

CT3002A.jpg
Battery Test System CT3002A (for current 200mA~3A, 2U, ~30lbs)

Applications of Battery Test System CT3002A

  • Coin cell test
  • Pouch cell test
  • Cylindrical cell test
  • Flow cell test
  • Constant voltage or constant current power sources for electrolysis
ModelCT3002A/CT3002AU
Current RangeCT3002A
Range 1: 5A/3A/2A/1A/500mA
Range 2: 500mA/300mA/200mA/100mA/50mA

CT3002AU
Range 1: 100mA/50mA/20mA/10mA
Range 2: 10mA/5mA/2mA/1mA
Current Accuracy±0.05%Full Scale
Voltage Range5V (or custom)
Voltage Accuracy ±0.05%Full Scale
Constant Power Accuracy ±0.1%Full Scale
Constant Resistance Accuracy ±0.1%Full Scale
Time Accuracy ±1s (no accumulative)
Sampling△t:20ms~7200s
△U:2mV~5V
△I:2uA~2000A
Charge ModeConstant current charge, Constant voltage charge, Constant power discharge, Constant resistance charge, C-rate charge
Charge Cut-offMain Channel: Step time, Voltage, Current, Capacity, Energy, -dV, Cycles, Cx, N1, N2, Coulombic efficiency, Capacity retention, etc.
Auxiliary Channel: Temperature, Voltage
Discharge ModeConstant current discharge, Constant voltage discharge, Constant power discharge, Constant resistance discharge, C-rate discharge
Discharge Cut-off Main Channel: Step time, Voltage, Current, Capacity, Energy, -dV, Cycles, Cx, N1, N2, Coulombic efficiency, Capacity retention, etc.
Auxiliary Channel: Temperature, Voltage
DCIR TestSupport
ProtectionsVoltage: over-charge, over-discharge;
Current: charge capacity, discharge capacity;
Capacity: charge capacity, discharge capacity;
Real-time voltage: voltage monitor during charge (voltage drop prohibited), voltage monitor during discharge (voltage increase prohibited);
Real-time current: current monitor during constant voltage charge (current increase prohibited);
Auxiliary voltage: max voltage, min voltage;
Auxiliary temperature: max temperature, min temperature
CyclesMax 650000 cycles, max 1100 steps in a cycle
No. of ChannelsFully independent 8 channels
CommunicationsSerial
No. of Aux ChannelsMax of 32 for the main channel
Data ExportExcel, txt or CSV format
Working Environment-10~40℃ (21~25℃ best), humidity<95%
Power InputAC220V50HZ/110V60HZ
Power30W for Ct3002AU, 180W/380W for CT3002A
DimensionCT3002AU (18”x9”x2”, W*L*H, ~10 lbs or 45*23*5cm, 4kg)
CT3002A (18”x13”x4”, W*L*H, 30~40 lbs or 45*33*10cm, 15~18kg)