This electrode sheet is based on copper foil coated with Si-C material on a single side and is used as the cathode of Li-Ion battery – 5 sheets/pack
Because it is a single-sided pole sheet, curling may occur after calendering. The sheets were calendered in a controlled manner so curling does not happen. Calendering is strongly suggested at the customer’s site to improve the packing density, electronic conductivity, and binding of electrode materials.
- Un-calendered electrode needs to be calendered at the customer’s site before use.
- The areal density should be determined according to the actual weighing results.
- The electrode needs to be dried in a vacuum at 105℃ for 4h before being transferred into a glovebox.
- This positive sheet can be matched with our cathode sheets.
- The coating areal density does not include the copper current collector.
- Theoretical areal capacity by mAh/cm2 = coating areal density by mg/cm2 * Proportion of active loading * specific capacity by mAh/g
- The theoretical active loading (mg) = coating areal density by mg/cm2 * proportion of active loading * small disc area by cm2
Sheet name | Si-C Anode Sheet with Copper Foil |
SKU | LB-SC0101 |
Current Collector Thickness (um) | 8 |
Current Collector Area Density (mg/cm2) | 7.3 |
Area Density of the Coating (mg/cm2) | 4.45 |
Active Material Specific Capacity (mAh/g) | 420 mAh/g (0.05~2.0V) |
Active Material in the Coating | 95% |
Recommended Packing Density (g/cc) | 1.3~1.55 |
Area capacity (mAh/cm2) | 1.78 |
Testing | Room temperature 25℃, 0.1/0.1 C, 0.05~2.0 V |
Sheet Size (Coating) | 10*10 cm |
Warranty | One year (vacuum package storage) and it is recommended to use up within one month after opening |
Instruction | 1. The sheet needs to be calendered according to the recommended packing density. 2. The surface density needs to be determined according to the actual weighing result. 3. Before putting it into the glove box, the punched electrode needs to be vacuum-baked at 105°C for 4 hours. |